Burners

Providing a versatile range of burners that can be tailor-made to suit any on-site requirements and fire a vast range of fuels.


Product(s)

High turndowns typically between 4:1 and 10:1

Pressure

Standard 15 PSIG to 300 PSIG (higher on request).

Codes

ASME, NATIONAL BOARD or as specified. Complies with local code requirements as applicable.

Fuels

Natural gas, propane, Number 2 oil, Hydrogen.

Efficiency

Fuel savings of 10-35% can be achieved.

Environmental

Lower C02 emissions and increase efficiency.


We optimize your boiler’s performance to support uninterrupted business

  • Redesigned combustion air blower ensures quiet operation.
  • Redesigned damper blades on combustion blower provide lower excess air levels.
  • Redesigned burner increases efficiency.
  • PLC based flame safeguard with optional linkage-less control. 
  • 4-20 ma modulation for feedback to PLC based lead/Lag control.
  • Completely flexible on burner management systems.
  • Solid state coil temperature system with individual temperature readouts and set points.
  • Air cooled circulating pump.

Standard Equipment Features

  • Fully modulating burner with 10-1 turn down on Natural Gas, propane and #2 Oil.
  • Switch controls and warning devises located in a central control panel at the front of the boiler skid for ease of operation and trouble shooting. 
  • All coils have individual monitoring sensors. 
  • Automatic timer controlled bottom blow down. 
  • Manual continuous blow down or optional automatic TDS control available.
  • Steam separation drum guarantees 99% plus dry saturated steam. 
  • Heavy duty gauge glass assembly.
  • Rear door access at floor level without disturbing refractory seal. 
  • All electrical boxes are oil/dust tight. 
  • All electrical conduit liquid tight.
  • Separate high voltage side panel.
  • Combustion air blower at floor level for ease of inspection and maintenance.
  • Recirculating pump and combustion blower direct drive.
  • Most service connections located at common junction point.
  • Double walled boiler shell preheats combustion air and cools outer casing, 
  • thereby minimizing radiation losses. 
  • Fuel to steam efficiencies up to 85% with heat recovery.

Add on Ancillary Equipment

Therm-O-Pac Packaged Deaerators produce water with oxygen content less than…

Preheat or process water from waste heat, three to seven percent average fuel savings…

Let’s connect and work together