Burners
Providing a versatile range of burners that can be tailor-made to suit any on-site requirements and fire a vast range of fuels.
Product(s)
High turndowns typically between 4:1 and 10:1
Pressure
Standard 15 PSIG to 300 PSIG (higher on request).
Codes
ASME, NATIONAL BOARD or as specified. Complies with local code requirements as applicable.
Fuels
Natural gas, propane, Number 2 oil, Hydrogen.
Efficiency
Fuel savings of 10-35% can be achieved.
Environmental
Lower C02 emissions and increase efficiency.
We optimize your boiler’s performance to support uninterrupted business
- Redesigned combustion air blower ensures quiet operation.
- Redesigned damper blades on combustion blower provide lower excess air levels.
- Redesigned burner increases efficiency.
- PLC based flame safeguard with optional linkage-less control.
- 4-20 ma modulation for feedback to PLC based lead/Lag control.
- Completely flexible on burner management systems.
- Solid state coil temperature system with individual temperature readouts and set points.
- Air cooled circulating pump.
Standard Equipment Features
- Fully modulating burner with 10-1 turn down on Natural Gas, propane and #2 Oil.
- Switch controls and warning devises located in a central control panel at the front of the boiler skid for ease of operation and trouble shooting.
- All coils have individual monitoring sensors.
- Automatic timer controlled bottom blow down.
- Manual continuous blow down or optional automatic TDS control available.
- Steam separation drum guarantees 99% plus dry saturated steam.
- Heavy duty gauge glass assembly.
- Rear door access at floor level without disturbing refractory seal.
- All electrical boxes are oil/dust tight.
- All electrical conduit liquid tight.
- Separate high voltage side panel.
- Combustion air blower at floor level for ease of inspection and maintenance.
- Recirculating pump and combustion blower direct drive.
- Most service connections located at common junction point.
- Double walled boiler shell preheats combustion air and cools outer casing,
- thereby minimizing radiation losses.
- Fuel to steam efficiencies up to 85% with heat recovery.
Add on Ancillary Equipment
Packaged Deaerators
Therm-O-Pac Packaged Deaerators produce water with oxygen content less than…
Thermiser Heat Recovery
Preheat or process water from waste heat, three to seven percent average fuel savings…
Let’s connect and work together
Our team can provide a qualified and optimized service experience.